 | Remove main burners, clean and inspect for damage. |
 | Clean and inspect gas injector(s). |
 | Dismantle and clean pilot assembly and gas injector. |
 | Reassemble burners and pilot assembly. |
 | Check condition of ignition leads and electrode. |
 | Clean the heat exchanger. |
 | Refit burner assemblies and check seals. |
 | Test disturbed gas joints for leaks. |
 | Check appliance case and seals (where appliance is room-sealed) for
damage and correct assembly. |
 | Check and adjust pilot flame. |
 | Check operation of thermocouple (flame supervision device). |
 | Measure gas pressure and flow rate, and adjust if necessary. |
 | Inspect/test flue for faults/correct operation. |
 | Inspect flue terminal for correct location and protection. |
 | Check system bypass valve (if fitted) is correctly adjusted. |
 | Check sealed system (if fitted) is at correct pressure. |
 | Advise user to have the system checked at least every twelve months or
as specified my manufacturer. |
 | Advise user of any defects found in writing. |
 | Apply the Industry Unsafe Situations Procedure if necessary. |